-
OVT-80K Insulation Oil Tester
OVT-80K Insulating Oil Dielectric Strength Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance.
-
TWR-S Transformer Turns Ratio Tester
TWR-S Transformer Turns Ratio Tester can be used for three-phase transformer testing in power systems, especially for Z-type winding transformers, rectifier transformers and Scott, reverse Scott, and balanced transformer testing in railway electrical systems. It is an ideal transformer ratio group polarity tester for power systems, transformer manufacturers and railway electrical systems.
-
GDYL-12kV/100pF Calibration Standard
The Standard Capacitor is a calibration instrument. It is standard capacitor for tan delta. When calibrating the test result, it can be tested as test object. User can compare the measured test result with former result.
-
GDZRC-40A Series DC Winding Resistance Tester
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment.
-
GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)
GD6100 is high-precision instrument for testing dielectric loss angle and volume resistivity of insulating oil or other insulating liquids.
-
GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV
There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.
-
GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester
GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
-
GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester
GD6100C Automatic Precision Oil Dielectric Loss Tester, is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids.
-
GD6100D Insulation Oil Tan Delta Tester
In the preventive test of electrical equipment insulation, periodic measurement of insulating oil parameters of electrical equipment is required. The measurement of dielectric loss and resistivity of insulating oil is one of the most important items. For a long time, most of them have been measured by the bridge method, which is cumbersome to operate, and the measurement accuracy is affected by many factors, resulting in large measurement errors.
-
GDZRC-50U DC Winding Resistance Tester
GDZRC-50U DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
-
GDBT Series Transformer Test Bench
GDBT Transformer test system can conduct all routine tests for transformers, including No-load and load test, Induced voltage test, Power frequency withstand voltage test, partial discharge test, DC resistance test, turns ratio test, temperature rising test etc.
-
GDKC-5000 Transformer On Load Tap Changer Tester
GDKC-5000 Transformer On Load Tap Changer Tester can accurately measure the transient time, transient waveform, transient resistance, three-phase synchronization and other parameters of the load tap changer. It is an ideal device for testing load tap changer. It meets the requirements of checking the action sequence of load tap changer and measuring of switching time.